For mantel clearances see figure 9 on page 1.
Gas fireplace insert clearance to combustibles.
This duluth forge full size 400 series vent this duluth forge full size 400 series vent free zero clearance fireplace insert allows you to build a custom fireplace for your home.
2114 3 masonry built fireplaces 4114 3 10 all combustible mantels and similar trim shall be kept at least 6 inches from the fireplace opening.
Parts of the mantel assembly located along the sides of the fireplace opening which project more than 1 1 2 inches 38mm from the face of the fireplace shall have additional clearance equal to the.
Firestops are required at each floor level and whenever passing through a wall.
Established in 1927 heatilator has built a long standing reputation for providing quality dependable hearth products at unbeatable values.
Why do contractors architects and homebuyers trust heatilator.
Because we mix value with dependability.
Clearances refer to how far materials have to be from your fireplace.
All fireplaces should have a noncombustible hearth extension.
Combustible material includes all wood trim framing mantels and anything else that can ignite and burn.
Clearances from the top of the fireplace opening to the ceiling should not be less than 36.
Each 1 8 inch that trim or another combustible material protrudes requires an extra inch of clearance.
Maintain clearances to combustibles.
Must use optional rigid pipe adaptor when using rigid vent systems part 510 994.
Figure 6 minimum clearance for combustible to wall minimum 16 from side wall example minimum clearance to combustible materials top left and right sides bottom and rear front 36 6 0 36.
All combustible mantel surrounds and shelves must be kept at least 12 inches from the opening of your fireplace top and sides.
For instance in the case of firerock building materials the minimum clearance to combustibles and framing from the firebox and smoke chamber is 1 inch.
Rigid pipe venting arrangements vertical terminations.
Heatilator fireplaces and inserts.
Wood framing drywall touching the back and sides of the unit without fear of heat damage.
Clearances vary by manufacturer and quality of materials used.
The insert is zero clearance approved so it can be framed without adding air gaps or spacing on the sides and top of the unit.
P36 p36e gas fireplace vent must be supported at offsets.
In addition if the side panels of your mantel project more than 1 1 2 inches from the fireplace facing you will need additional clearance equal to this projection.
Most zero clearance fireplaces can have combustible materials e g.